In the event of a leak in a pipe element, a valve must open as soon as the pressure falls below a predefined level. This causes air to flow through the valve,which is intended to prevent the pipework from imploding. This raises the question of whether the valve is sufficiently large and how quickly it opens.
Therefore,the valve lift as a function of time was computed based on the pressure before and after the valve, the spring force and the friction losses. A constant volumetric outflow rate of air was assumed to model the real case. Furthermore,constant ambient pressure and temperature conditions have been assumed at thei nlet of the pipe.
Thefollowing picture shows the CAD and the CFD model of the valve.

The pictureb elow shows the resulting valve lift as a function of time. It can be seen that the valve opens fast almost up to the designed maximum valve lift, followed by a decreasing valve lift due to the inflowing air and opens again up to the maximum valve lift.

The following video shows the pressure, the velocity magnitude and the temperature during the inflow process simultaneously.
In a spring-loaded valve, the flow determines the force on the valve disc, and the movement of the disc in turn changes the flow. Both have to be calculated together. A calculation with a fixed lift cannot capture this feedback and therefore overestimates or underestimates how fast and how far the valve opens.
For example, whether a valve is large enough, how fast it opens and whether it tends to flutter.
No. The same principle applies to flaps, check valves and other moving parts in a flow.
Further reading: CFD simulation of a valve · Automation of CFD simulation
Do not hesitate to contact us in case you have any questions or if you need some more information.